Test E: Warning Indicator Off With Ignition On
Turn ignition off. Disconnect generator 3-pin connector. Connect a fused (15-amp) jumper wire at generator terminal "I" (Light Green/Red wire) to ground. See Figure or Figure . Turn ignition on and observe warning indicator. If warning indicator illuminates, replace generator. See GENERATOR under REMOVAL & INSTALLATION. If warning indicator does not illuminate, repair warning indicator and/or circuit as necessary. See appropriate INSTRUMENT PANELS article in ACCESSORIES & EQUIPMENT.