SPECIFICATIONS

Application Specification
Compressor Type Ford FS-10 10-Cyl.
Compressor Belt Tension (2)
Cycling Switch Pressures (1)
Open 21-23 psi (1.47-1.62 kg/cm2 )
Close 42 psi (2.95 kg/cm2 )
Pressure Relief Valve Open (Minimum) 550 psi (38.67 kg/cm2 )
System Oil Capacity (3) 7.5 ozs.
Refrigerant (R-134a) Capacity 38.0 ozs.
System Operating Pressures (1)
High Side 125-230 psi (8.8-16.2 kg/cm2 )
Low Side 22-45 psi (1.5-3.2 kg/cm2 )
(1) Specification is with ambient temperature at 80°F (27°C) and engine speed at 1200 RPM.
(2) Serpentine belt tension is maintained by automatic tensioner pulley.
(3) Use YN-12b PAG Oil (Part No. F7AZ-19589-DA).