Removal & Installation
- Disconnect battery ground cable. Disconnect blower motor from main wiring harness at snap-lock connector. Depress locking tab and slide 2 harness connectors from face of blower motor. Remove cooling tube from blower motor.
- Remove 4 retaining screws from blower motor mounting plate. Remove wiring support bracket. Lift assembly up and out of housing assembly. To install, reverse removal procedure.