LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2002 >> Crown Victoria Base, 4.6 9 >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC Systems - Compressor Servicing >> ZEXEL (SATURN - Variable Displacement Type) >> Pressure Relief Valve >> Installation

Pressure Relief Valve: Installation

NOTE: Use R-12 refrigerant oil (mineral) to lubricate O-rings. Use of R-134a (PAG) oil will cause premature corrosion of fitting joints.
  1. Lubricate the pressure relief valve O-ring with new R-12 mineral compressor oil.
  2. Install the pressure relief valve to the compressor hose. See Fig 1. Tighten the pressure relief valve to 89 INCH Lbs. (10 N.m).
  3. Lower the vehicle.
  4. Evacuate and charge the A/C system. See RECOVERY/EVACUATION & RECHARGING in GENERAL SERVICING PROCEDURES article in GENERAL SERVICING.
  5. Test the affected A/C joint for leaks using a leak detector. See LEAK TESTING in GENERAL SERVICING PROCEDURES article in GENERAL SERVICING.
Fig 1: Removing & Installing Pressure Relief Valve
G00233788Courtesy of GENERAL MOTORS CORP.