Removal & Installation: Compressor: Installation
- To install, reverse removal procedure. If amount of oil drained from old A/C compressor is between 3-5 ounces (85-142 ml), pour same amount plus one ounce (30 ml) of clean PAG Refrigerant Compressor Oil or equivalent into new A/C compressor.
- If amount of oil that was removed from old A/C compressor is greater than 5 ounces (142 ml), pour same amount drained of clean PAG Refrigerant Compressor Oil or equivalent into new A/C compressor. If amount of oil that was removed from old A/C compressor is less than 3 ounces (85 ml), pour 3 ounces (85 ml) of clean PAG Refrigerant Compressor Oil or equivalent into new A/C compressor.
- Install new "O" ring seals lubricated in clean PAG oil or equivalent. If filtering of refrigerant system is not to be performed, evacuate, leak test, and charge refrigerant system. See RECOVERY, EVACUATION & RECHARGING in GENERAL SERVICING PROCEDURES article in GENERAL SERVICING.