Removal & Installation (Evaporator-To-Compressor Suction)
- Discharge A/C system, using approved recovery/recycling equipment. See RECOVERY, EVACUATION & RECHARGING in GENERAL SERVICING PROCEDURES article in GENERAL SERVICING. Disconnect evaporator to compressor suction line spring lock coupling from accumulator-drier. See Figure.
- Disconnect evaporator to compressor suction line spring lock coupling from compressor manifold and tube assembly and remove evaporator to compressor suction line. See Fig 1.
- To install, reverse removal procedure. Lubricate NEW "O" ring seal with PAG Refrigerant Compressor Oil or equivalent. Add 2 ounces (60 ml) of clean PAG Refrigerant Compressor Oil or equivalent to accumulator-drier inlet tube. Evacuate, leak test, and charge refrigerant system.
Courtesy of FORD MOTOR CO.