LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2002 >> Crown Victoria Base, 4.6 9 >> Repair and Diagnosis >> Engine Performance >> Engine Controls - Pin Voltage Charts >> PID Definitions & Pin Voltage/PID Values >> Pin Voltage/PID Value Tables >> Sable & Taurus >> Sable & TAURUS 3.0L 2V (Flexible Fuel & Gasoline)

Sable & TAURUS 3.0L 2V (Flexible Fuel & Gasoline)

NOTE: All generic OBD-II readings under no load (Park or Neutral).
SABLE & TAURUS 3.0L 2V (FLEXIBLE FUEL & GASOLINE) - INPUTS

PCM Pin No./PID Only Sensors/Inputs Units Measured/PID KOEO/PID Hot Idle/PID 30 MPH/PID 55 MPH/PID
3 TR1 DCV 0 0 10.5 10.5
6 TSS Hz/RPM 0 50-65/820-900 82-99/1400-1500 88-120/1740-1900
12 FLI V/FLI DCV/Percent 1.7/50 1.7/50 1.7/50 1.7/50
13 FEPS DCV .5-.6 .5-.6 .5-.6 .5-.6
17 PATSIN (1) (1) (1) (1) (1)
21 CKP (+) Hz 0 410-510 810-950 1050-1820
35 O2S12 DCV .1 (2) (2) (2)
37 TFT DCV/°F .5-2.0/110-210 .5-2.0/110-210 .5-2.0/110-210 .5-2.0/110-210
38 ECT DCV/°F .4-1.0/160-200 .4-1.0/160-200 .4-1.0/160-200 .4-1.0/160-200
39 IAT DCV/°F 1.7-3.5/50-120 (3) 1.7-3.5/50-120 (3) 1.7-3.5/50-120 (3) (3) 1.7-3.5/50-120
40 FPM DCV/Percent 0-7/85-115 0-7/85-115 0-7/85-115 0-7/85-115
41 ACCS DCV/OFF-ON .1/OFF VBAT/ON (4) .1/OFF .1/OFF
45 GFS Hz/Percent 0 130/30 130/27 130/23
49 TR2 DCV 0 0 10.5 10.5
50 TR4 DCV 0 0 10.5 10.5
57 KS1 DCV 0 0 0 0
60 O2S11 DCV 0 Switching (5) Switching (5) (5) Switching
61 O2S22 DCV 0 (2) (2) (2)
62 FTP V/FTP DCV/In. H2 O 2.6/.51 2.6/.48 2.6/.49 2.6/.44
63 FRP V/FRP DCV/psi 3.7/55 3.6/54 2.8/42 2.7/40
64 TR V/TR DCV/MODE 0/PARK 0/PARK 1.7/OD 1.7/OD
65 DPFEGR DCV .95-1.05 .95-1.05 .95-4.65 .95-4.65
66 ACET DCV 4.95-5.15 4.95-5.15 4.95-5.15 4.95-5.15
84 OSS Hz/RPM 0 0 300/1750 500/2550
85 CID Hz 0 6-8 12-14 13-16
86 ACP DCV/OPEN-CLOSED VBAT/OPEN VBAT/OPEN VBAT/OPEN VBAT/OPEN
87 O2S21 DCV 0 Switching (5) Switching (5) (5) Switching
88 MAF V DCV 0 .6-.9 1.0-1.5 1.1-2.0
89 TP V DCV .53-1.27 .53-1.27 .8-1.2 .8-1.2
92 BPP DCV/OFF-ON .1/OFF VBAT/ON (6) .1/OFF .1/OFF
PID CPP/PNP OFF-ON ON ON OFF OFF
PID GEAR GEAR 1 1 3 4
PID LOAD Percent (7) 10-20 16-30 13-50
PID MISF OFF-ON OFF OFF OFF OFF
PID OCTADJS NO RETARD/RETARD NO RETARD NO RETARD NO RETARD NO RETARD
PID RPM RPM 0 660-800 1440-1625 1830-1970
PID VSS MPH 0 0 30 55
(1) See appropriate ANTI-THEFT SYSTEMS article in ACCESSORIES & EQUIPMENT.
(2) Downstream O2S(s) will stay close to a constant voltage when catalyst monitor is off (positive value only). When catalyst monitor is on, O2S will switch rich to lean above and below .45 volt DC and never be a negative value.
(3) Value is dependent upon ambient air temperature and may fall outside of range.
(4) A/C on.
(5) O2S should switch from rich to lean at least once every 3 seconds. O2S voltage should toggle above and below .45 volt DC and never be a negative value. Valid O2S switching only occurs during closed loop fuel control.
(6) Brake pedal applied.
(7) Value is not useful under this condition.
SABLE & TAURUS 3.0L 2V (FLEXIBLE FUEL & GASOLINE) - OUTPUTS

PCM Pin No./PID Only Actuators/Outputs Units Measured/PID KOEO/PID Hot Idle/PID 30 MPH/PID 55 MPH/PID
1 SS2 DCV/OFF-ON .1/ON .1/ON VBAT/OFF .1/ON
2 MIL DCV/OFF-ON .1/OFF VBAT/OFF VBAT/OFF VBAT/OFF
26 CDA DCV VBAT VBAT VBAT VBAT
27 SS1 DCV/OFF-ON VBAT/OFF VBAT/OFF .1/ON .1/ON
28 LFC DCV/OFF-ON VBAT/OFF (1) .1/ON VBAT/OFF VBAT/OFF
46 HFC DCV/OFF-ON VBAT/OFF (1) .1/ON VBAT/OFF VBAT/OFF
47 EGRVR DCV/Percent VBAT/0 VBAT/0 10.5-VBAT/0-40 10.4-11.8/36-50
48 CTO Hz 0 35-50 65-78 91-105
52 CDB DCV VBAT VBAT VBAT VBAT
53 SS3 DCV/OFF-ON VBAT/OFF VBAT/OFF .1/ON .1/ON
54 TCC DCV/Percent VBAT/0 VBAT/0 11/42 .4/90-100
56 EVAPPDC Hz/Percent 0 0-10/0-100 0-10/0-100 0-10/0-100
67 EVAPCV Hz/Percent 0 0-10/0-100 0-10/0-100 0-10/0-100
68 VSO Hz 0 0 65 125
69 WAC DCV/OFF-ON VBAT/OFF (2) .1/ON VBAT/OFF VBAT/OFF
71 VPWR DCV VBAT VBAT VBAT VBAT
73 INJ5 mS 0 3.8-4.7 3.9-8.0 3-9
74 INJ3 mS 0 3.8-4.7 3.9-8.0 3-9
75 INJ1 mS 0 3.8-4.7 3.9-8.0 3-9
78 CDC DCV VBAT VBAT VBAT VBAT
80 FP DCV/Percent 3.6/75 .1/100 .1/100 .1/100
81 EPC (AX4N) DCV/psi 7.4/15 10.6/40 8.5/15 9.7/42
81 EPC (AX4S) DCV/psi 7.4/15 9/15 9.4/17 10.7/40
83 IAC DCV/Percent VBAT/0 8.4/40 7.5-10/40-60 8.8-10.5/40-57
90 VREF DCV 5 5 5 5
93 HTR11 DCV/OFF-ON VBAT/OFF SWITCH SWITCH SWITCH
94 HTR21 DCV/OFF-ON VBAT/OFF SWITCH SWITCH SWITCH
95 HTR12 DCV/OFF-ON VBAT/OFF .2/ON .2/ON .2/ON
96 HTR22 DCV/OFF-ON VBAT/OFF .2/ON .2/ON .2/ON
99 INJ6 mS 0 3.8-4.7 3.9-8.0 3-9
100 INJ4 mS 0 3.8-4.7 3.9-8.0 3-9
101 INJ2 mS 0 3.8-4.7 3.9-8.0 3-9
PID FUELPW1 mS (3) 3.3-4.7 3.9-8.0 3-9
PID FUELPW2 mS (3) 3.3-4.7 3.9-8.0 3-9
PID LONGFT1 Percent -20 To +20 -20 To +20 -20 To +20 -20 To +20
PID LONGFT2 Percent -20 To +20 -20 To +20 -20 To +20 -20 To +20
PID SHRTFT1 Percent (3) -10 To +10 -10 To +10 -10 To +10
PID SHRTFT2 Percent (3) -10 To +10 -10 To +10 -10 To +10
PID SPARKADV Degrees 0 24-30 34-42 33-46
(1) Cooling fan on (single, low or high speed).
(2) A/C on.
(3) Value is not useful under this condition.
SABLE & TAURUS 3.0L 2V (FLEXIBLE FUEL & GASOLINE) - GENERIC OBD-II PID VALUES

PID Measured Units Hot Idle 2500 RPM
LONGFT1 Percent -20 To +20 -20 To +20
LONGFT2 Percent -20 To +20 -20 To +20
LOAD Percent 17-25 15-22
MAF Grams/Sec. 4-5 11-13
SHRTFT1 Percent -10 To +10 -10 To +10
SHRTFT2 Percent -10 To +10 -10 To +10
SHRTFT11 Percent -10 To +10 -10 To +10
SHRTFT12 Percent 95-100 95-100
SHRTFT21 Percent -10 To +10 -10 To +10
SPARKADV Degrees 24-30 44