LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2002 >> Crown Victoria Base, 4.6 9 >> Repair and Diagnosis >> Engine Performance >> Engine Controls - Pin Voltage Charts >> PID Definitions & Pin Voltage/PID Values >> Pin Voltage/PID Value Tables >> Sable & Taurus >> Sable & TAURUS 3.0L 4V

Sable & TAURUS 3.0L 4V

NOTE: All generic OBD-II readings under no load (Park or Neutral).
SABLE & TAURUS 3.0L 4V - INPUTS

PCM Pin No./PID Only Sensors/Inputs Units Measured/PID KOEO/PID Hot Idle/PID 30 MPH/PID 55 MPH/PID
5 AIR M DCV/OFF-ON .1/OFF .1/OFF .1/OFF .1/OFF
9 FLI V/FLI DCV/Percent 1.7/50 1.7/50 1.7/50 1.7/50
13 FEPS DCV .5-.6 .5-.6 .5-.6 .5-.6
17 PATSIN (1) (1) (1) (1) (1)
21 CKP (+) Hz 0 390-520 850-1120 1140-1220
29 TCS DCV/OFF-ON .1/OFF VBAT/ON (2) .1/OFF .1/OFF
31 PSP V/PSP DCV/LOW-HIGH .1/LOW VBAT/HIGH (3) .1/LOW .1/LOW
34 TR1 DCV 0 0 10.7 10.7
35 O2S12 DCV .1 (4) (4) (4)
37 TFT DCV/°F .5-2.0/110-210 .5-2.0/110-210 .5-2.0/110-210 .5-2.0/110-210
38 ECT DCV/°F .4-1.0/160-200 .4-1.0/160-200 .4-1.0/160-200 .4-1.0/160-200
40 FPM DCV/Percent 0-7/85-115 0-7/85-115 0-7/85-115 0-7/85-115
41 ACCS DCV/OFF-ON .1/OFF VBAT/ON (5) .1/OFF .1/OFF
45 GFS Hz/Percent 0 130/30 130/27 130/23
49 TR2 DCV 0 0 10.7 10.7
50 TR4 DCV 0 0 10.7 10.7
57 KS1 DCV 0 0 0 0
58 TSS Hz/RPM 0 43/700 85-105/1480-1570 110-125/1690-2000
60 02S11 DCV 0 Switching (6) Switching (6) (6) Switching
61 02S22 DCV 0 (4) (4) (4)
62 FTP V/FTP DCV/In. H2 O 2.6/.41 2.6/.41 2.6/.41 2.6/.41
63 FRP V/FRP DCV/OFF-ON 3.15/46 2.74/39 2.88/41 2.86/40
64 TR V/TR DCV/MODE 4.4/PARK 4.4/PARK 2.1/OD 2.1/OD
65 DPFEGR DCV .95-1.05 .95-1.05 .95-4.65 .95-4.65
66 ACET DCV 4.95-5.15 4.95-5.15 4.95-5.15 4.95-5.15
84 OSS Hz/RPM 0 0 300/1650 506/2600
85 CID Hz 0 5-7 10-13 14-17
86 ACP V/ACP DCV/OPEN-CLOSED VBAT/OPEN VBAT/OPEN VBAT/OPEN VBAT/OPEN
87 O2S21 DCV 0 Switching (6) Switching (6) (6) Switching
88 MAF V DCV 0 .5-.7 .7-1.5 1.3-2.0
89 TP V DCV .53-1.27 .53-1.27 .8-1.1 1.0-1.5
92 BPP DCV/OFF-ON .1/OFF VBAT/ON (7) .1/OFF .1/OFF
PID CPP/PNP OFF-ON ON ON OFF OFF
PID IAT °F 50-120 (8) 50-120 (8) 50-120 (8) 50-120 (8)
PID GEAR GEAR 1 1 3 4
PID LOAD Percent (9) 15-20 20-35 15-35
PID MISF OFF-ON OFF OFF OFF OFF
PID OCTADJS NO RETARD/RETARD NO RETARD NO RETARD NO RETARD NO RETARD
PID RPM RPM 0 700-730 1350-1650 1800-2060
PID VSS MPH 0 0 30 55
(1) See appropriate ANTI-THEFT SYSTEMS article in ACCESSORIES & EQUIPMENT.
(2) While pressing Transmission Control Switch or switching to manual drive mode.
(3) Steering wheel turned.
(4) Downstream O2S(s) will stay close to a constant voltage when catalyst monitor is off (positive value only). When catalyst monitor is on, O2S will switch rich to lean above and below .45 volt DC and never be a negative value.
(5) A/C on.
(6) O2S should switch from rich to lean at least once every 3 seconds. O2S voltage should toggle above and below .45 volt DC and never be a negative value. Valid O2S switching only occurs during closed loop fuel control.
(7) Brake pedal applied.
(8) Value is dependent upon ambient air temperature and may fall outside of range.
(9) Value is not useful under this condition.
SABLE & TAURUS 3.0L 4V - OUTPUTS

PCM Pin No./PID Only Actuators/Outputs Units Measured/PID KOEO/PID Hot Idle/PID 30 MPH/PID 55 MPH/PID
1 CDD DCV VBAT VBAT VBAT VBAT
2 MIL DCV/OFF-ON .1/OFF VBAT/OFF VBAT/OFF VBAT/OFF
6 SS1 DCV/OFF-ON VBAT/OFF VBAT/OFF .1/ON .1/ON
11 SS2 DCV/OFF-ON .1/ON .1/ON VBAT/OFF .1/ON
18 PATSOUT (1) (1) (1) (1) (1)
20 GENFDC Hz/Percent 0 0 0 0
26 CDA DCV VBAT VBAT VBAT VBAT
27 CDE DCV VBAT VBAT VBAT VBAT
28 LFC DCV/OFF-ON VBAT/OFF .1/ON (2) VBAT/OFF VBAT/OFF
30 PATSIL (1) (1) (1) (1) (1)
42 MFC DCV/OFF-ON VBAT/OFF .1/ON (2) VBAT/OFF VBAT/OFF
44 PATSTRT (1) (1) (1) (1) (1)
46 HFC DCV/OFF-ON VBAT/OFF .1/ON (2) VBAT/OFF VBAT/OFF
47 EGRVR DCV/Percent VBAT/0 VBAT/0 10.5-VBAT/0-50 9.5-VBAT/0-60
48 CTO Hz 0 33-45 75-85 92-120
52 CDB DCV VBAT VBAT VBAT VBAT
53 CDF DCV VBAT VBAT VBAT VBAT
20 SS3 DCV/OFF-ON VBAT/OFF VBAT/OFF .1/ON .1/ON
54 TCC DCV/Percent VBAT/0 VBAT/0 .2/100 .2/100
56 EVAPPDC Hz/Percent 0 0-10/0-100 0-10/0-100 0-10/0-100
67 EVAPCV Hz/Percent 0 0-10/0-100 0-10/0-100 0-10/0-100
68 VSO Hz/RPM 0 0 65 125
69 WAC DCV/OFF-ON VBAT/OFF .1/ON (3) VBAT/OFF VBAT/OFF
79 TCIL DCV/OFF-ON VBAT/OFF VBAT/OFF VBAT/OFF VBAT/OFF
73 INJ5 mS 0 2.2-2.7 2.3-5.5 2-7
74 INJ3 mS 0 2.2-2.7 2.3-5.5 2-7
75 INJ1 mS 0 2.2-2.7 2.3-5.5 2-7
78 CDC DCV VBAT VBAT VBAT VBAT
80 FP DCV/Percent 3.6/75 .1/100 .1/100 .1/100
81 EPC DCV/Percent 7.5/15 9/15 8.9-10.1/16-25 9.2/27
83 IAC DCV/Percent VBAT/0 9.8-11.2/25-35 7.5-10/30-55 7.2-8.0/50-59
93 HTR11 DCV/OFF-ON VBAT/OFF Switching Switching Switching
94 HTR21 DCV/OFF-ON VBAT/OFF Switching Switching Switching
95 HTR12 DCV/OFF-ON VBAT/OFF .2/ON .2/ON .2/ON
96 HTR22 DCV/OFF-ON VBAT/OFF .2/ON .2/ON .2/ON
99 INJ6 mS 0 2.2-2.7 2.3-5.5 2-7
100 INJ4 mS 0 2.2-2.7 2.3-5.5 2-7
101 INJ2 mS 0 2.2-2.7 2.3-5.5 2-7
PID FUELPW1 mS (4) 2.2-3.4 2.3-5.5 2-7
PID FUELPW2 mS (4) 2.2-3.3 2.3-5.5 2-7
PID LONGFT1 Percent -20 To +20 -20 To +20 -20 To +20 -20 To +20
PID LONGFT2 Percent -20 To +20 -20 To +20 -20 To +20 -20 To +20
PID SHRTFT1 Percent (4) -10 To +10 -10 To +10 -10 To +10
PID SHRTFT2 Percent (4) -10 To +10 -10 To +10 -10 To +10
PID SPARKADV Degrees 0 12-27 25-42 20-40
55 KAPWR DCV VBAT VBAT VBAT VBAT
71 VPWR DCV VBAT VBAT VBAT VBAT
90 VREF DCV 5 5 5 5
(1) See appropriate ANTI-THEFT SYSTEMS article in ACCESSORIES & EQUIPMENT.
(2) Cooling fan on (single, low or high speed).
(3) A/C on.
(4) Value is not useful under this condition.
SABLE & TAURUS 3.0L 4V - GENERIC OBD-II PID VALUES

PID Measured Units Hot Idle 2500 RPM
LONGFT1 Percent -20 To +20 -20 To +20
LONGFT2 Percent -20 To +20 -20 To +20
LOAD Percent 30-34 30-40
MAF Grams/Sec. 3.5-4.0 12-14
SHRTFT1 Percent -10 To +10 -10 To +10
SHRTFT2 Percent -10 To +10 -10 To +10
SHRTFT11 Percent -10 To +10 -10 To +10
SHRTFT12 Percent 95-100 95-100
SHRTFT21 Percent -10 To +10 -10 To +10
SHRTFT22 Percent 95-100 95-100
SPARKADV Degrees 12-17 35-40