Electronic Pressure Control Solenoid
The Electronic Pressure Control (EPC) solenoid receives signal from the PCM to control line pressure and 2-3 backout valve function. If EPC solenoid fails in ON position, transmission is operated in fail-safe mode. Minimum line pressure is present. If EPC solenoid fails in OFF position, line pressure is at maximum pressure. Harsh engagements and shifts will result.