Air Filter Element: Service and Repair
AIR CLEANER ELEMENT
Exploded View
Removal and Installation
1. NOTE: Do not disconnect the mass air flow sensor electrical connector.
Detach the wiring harness retainer from the air cleaner outlet pipe.
2. Loosen the clamp and disconnect the air cleaner outlet pipe from the air cleaner.
3. Unclip and remove the air cleaner cover.
4. Remove the air cleaner element.
5. NOTE: Clean the inside of the air cleaner tray.
To install, reverse the removal procedure.