Test E: The Low Washer Fluid Level Display Does Not Operate Correctly
PINPOINT TEST E: THE LOW WASHER FLUID LEVEL DISPLAY DOES NOT OPERATE CORRECTLYE1-E3:

E3-E5:

E6-E7:

Normal Conditions
The washer fluid level switch circuit 81 (RD/LG) is open when the washer fluid level is high. When the washer fluid level is low, the switch will close circuit 81 (RD/LG) with the ground circuit 1203 (BK/LB), to signal the message center to indicate the washer fluid level is low.
Possible Causes
- circuit 1203 (BK/LB) open
- circuit 81 (RD/LG) open or short to ground
- instrument cluster