Test H: The Low Brake Fluid Level Display Does Not Operate Correctly
Pinpoint Test H: The Low Brake Fluid Level Display Does Not Operate CorrectlyH1-H2:

Normal Conditions
The instrument cluster communicates the brake fluid level status to the message center.
Possible Causes
- instrument cluster