LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Infiniti >> 2008 >> M35 V6-3.5L (VQ35DE) >> Repair and Diagnosis >> Relays and Modules >> Relays and Modules - Lighting and Horns >> Headlamp Alignment Control Module >> Testing and Inspection >> Scan Tool Testing and Procedures >> Active Test

Active Test

ACTIVE TEST

CAUTION: Can be tested only when swivel actuator initialization is completed. If initialization is not completed, "RETRY COMMAND" is displayed and cannot be tested.

- LOW BEAM TEST RIGHT
Low beam headlamp (right) can be operated to swivel angle 0° by touching "ORIGIN", and to maximum angle by "PEAK".






- LOW BEAM TEST LEFT
Low beam headlamp (left) can be operated to swivel angle 0° by touching "ORIGIN", and to maximum angle by "PEAK".






- LEVELIZER TEST
Aiming motor drive signal can be changed to approx. 85% (ratio to IGN power supply) by touching "ORIGIN", and to approx. 15% by "PEAK". That angles headlamp LO up and down.