LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2016 >> CR-V EX, Eng CD K24W9, FWD >> Repair and Diagnosis (Single Page) >> Engine Performance >> Mode 6 - 2016 HONDA >> Mode $06 Information By Test >> A/F Sensor (Bank 2)

A/F Sensor (Bank 2)

DTC P0154: Monitor ID $05: Test ID $80

OBD Monitor ID $05 Test ID $80 Unit and Scaling ID $11
DTC P0154
Test Description Check of A/F sensor "non-activation" by monitoring the sensor non-activation time.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.1 (sec.)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.1 (sec.)
DTC P0154: Monitor ID $05: Test ID $80

OBD Monitor ID $05 Test ID $80 Unit and Scaling ID $14
DTC P0154
Test Description Check of A/F sensor element resistance after A/F sensor "non-activation". See Test ID $81 and $82 for "non-activation" criteria.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 1 (Ω)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 1 (Ω)
DTC P0154: Monitor ID $05: Test ID $82

OBD Monitor ID $05 Test ID $82 Unit and Scaling ID $0B
DTC P0154
Test Description Check of A/F sensor "non-activation" by monitoring the sensor cell voltage.
Store Timing Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.01 (V)
The lowest limit value: Output value (Decimal) x 0.01 (V)
The highest limit value: Output value (Decimal) x 0.01 (V)
DTC P2197: Monitor ID $05: Test ID $8D

OBD Monitor ID $05 Test ID $83 Unit and Scaling ID $0A
DTC P2197
Test Description Check of A/F sensor voltage when feedback condition is established.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.122 (mV)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.122 (mV)
DTC P2197: Monitor ID $05: Test ID $8D

OBD Monitor ID $05 Test ID $83 Unit and Scaling ID $8D
DTC P2197
Test Description Check of the A/F sensor "too lean" by monitoring the A/F sensor signal.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.003906 (mA)
The lowest limit value: Output value (Decimal) x 0.003906 (mA)
The highest limit value: Not applicable
DTC P2A03: Monitor ID $05: Test ID $84

OBD Monitor ID $05 Test ID $84 Unit and Scaling ID $0A
DTC P2A03
Test Description Check of A/F sensor voltage by monitoring the A/F sensor during fuel cut condition.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.122 (mV)
The lowest limit value: Output value (Decimal) x 0.122 (mV)
The highest limit value: Output value (Decimal) x 0.122 (mV)
DTC P2A03: Monitor ID $05: Test ID $84

OBD Monitor ID $05 Test ID $84 Unit and Scaling ID $8D
DTC P2A03
Test Description Check of A/F sensor rationality by monitoring the sensor signal during fuel cut condition.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.003906 (mA)
The lowest limit value: Output value (Decimal) x 0.003906 (mA)
The highest limit value: Output value (Decimal) x 0.003906 (mA)
DTC P1174: Monitor ID $05: Test ID $86

OBD Monitor ID $05 Test ID $86 Unit and Scaling ID $0A
DTC P1174
Test Description Check of A/F sensor voltage after A/F sensor once activation is determined in the drive cycle.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.122 (mV)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.122 (mV)
DTC P1174: Monitor ID $05: Test ID $86

OBD Monitor ID $05 Test ID $86 Unit and Scaling ID $8D
DTC P1174
Test Description Check of A/F sensor "out of range" by monitoring the sensor signal.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.003906 (mA)
The lowest limit value: Output value (Decimal) x 0.003906 (mA)
The highest limit value: Not applicable
DTC P0154: Monitor ID $05: Test ID $87

OBD Monitor ID $05 Test ID $87 Unit and Scaling ID $14
DTC P0154
Test Description Check of A/F sensor "non-activation" by monitoring the sensor element resistance during A/F feedback control.
Store Timing Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 1 (Ω)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 1 (Ω)
DTC P0154: Monitor ID $05: Test ID $88

OBD Monitor ID $05 Test ID $88 Unit and Scaling ID $0B
DTC P0154
Test Description Check of A/F sensor "non-activation" by monitoring the sensor cell voltage during A/F feedback control.
Store Timing Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.01 (V)
The lowest limit value: Output value (Decimal) x 0.01 (V)
The highest limit value: Output value (Decimal) x 0.01 (V)
DTC P0153: Monitor ID $05: Test ID $89

OBD Monitor ID $05 Test ID $89 Unit and Scaling ID $01
DTC P0153
Test Description Response check of A/F sensor by monitoring the amplitude of filtered sensor signal during stable driving condition.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: No unit
The lowest limit value: No unit
The highest limit value: Not applicable