LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2016 >> CR-V EX, Eng CD K24W9, FWD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System - Service Information >> Removal & Installation >> A/C Refrigerant Recovery/Evacuation/Charging >> Procedure

A/C Refrigerant Recovery/Evacuation/Charging: Procedure

GHH47473Courtesy of HONDA, U.S.A., INC.

NOTE: 

A more efficient way to measure moisture removal is with a special tool called a thermistor (compact electronic) vacuum gauge, measuring vacuum levels in microns. The robinair 48920T (ROB48920T) R134a A/C automatic recovery, recycle, recharge machine has a built-in thermistor (compact electronic) vacuum gauge. If you are using a different R134a A/C automatic recovery, recycle, recharge machine, a separate gauge, such as the ROB14777 may be used.

Connect the tool according to the manufacturers instructions and allow the vacuum pump to run until the gauge reads 750 microns.

Shut off and isolate the vacuum pump, then observe the gauge reading:

When an A/C System has been opened to the atmosphere, such as during installation or repair, it must be evacuated using an R-134a refrigerant recovery/recycling/charging station. If the system has been open for several days, replace the receiver/dryer* , drain the refrigerant oil, and add fresh oil . Then evacuate the system for several hours before charging it.