LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Alfa Romeo >> 2019 >> Giulia Base, AWD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating & Air Conditioning >> Distribution >> Outlet, Air >> Removal And Installation >> Air Outlets - Front Floor >> Removal

Air Outlets - Front Floor: Removal

WARNING:

To avoid serious or fatal injury on vehicles equipped with airbags, disable the Supplemental Restraint System (SRS) before attempting any steering wheel, steering column, airbags, airbag curtains, knee blocker, seat belt tensioner, impact sensor or instrument panel component diagnosis or service. Disconnect the Intelligent Battery Sensor (IBS)/negative battery cable assembly from the negative battery post, then wait two minutes for the system capacitor to discharge before performing further diagnosis or service. This is the only sure way to disable the SRS. Failure to take the proper precautions could result in accidental airbag deployment.

NOTE:

Right side shown in illustration, left side similar.

  1. Disconnect and isolate the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), disconnect the IBS connector first before disconnecting the negative battery cable.
  2. Remove the glove box. Refer to GLOVE BOX, INSTRUMENT PANEL, REMOVAL AND INSTALLATION .
    GC0197487Courtesy of CHRYSLER GROUP, LLC
  3. Using a suitable tool, release the left/right front floor air outlet push pin (1a).
  4. Remove the left/right front floor air outlet (2a) by releasing it from the HVAC housing (2b).