Low Or Empty Refrigerant System

NOTE:

This procedure should only be done after an A/C Performance Test has been conducted and a refrigerant system leak has NOT been found using the factory installed leak detection dye.

Do the following if the A/C compressor will not engage and a refrigerant leak in the A/C system is suspected but cannot be found using the factory installed leak detection dye.

  1. Recover, evacuate and recharge the refrigerant system. Refer to PLUMBING, STANDARD PROCEDURE .
  2. Operate the HVAC system with the engine at idle under the following conditions for at least 15 minutes:
    • Doors or windows open
    • Transmission in Park or Neutral with the parking brake set (depending on transmission application)
    • A/C heater controls set to outside air, full cool, panel mode, high blower and A/C compressor engaged
    • If equipped with rear A/C, set rear controls to full cool and high blower.
  3. Turn the engine OFF and return to. Refer to LEAK TEST .