LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Alfa Romeo >> 2019 >> Giulia Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 3 (2.9L - Engine (Service Information)) >> Lubrication >> Sensor, Oil Pressure >> Removal And Installation >> Right Cylinder Head Lifter Deactivation Circuit Oil Pressure Sensor

Right Cylinder Head Lifter Deactivation Circuit Oil Pressure Sensor

WARNING: This page is about a different variant/trim than selected.

REMOVAL 

  1. Disconnect and isolate the negative battery cable.
  2. Remove the right air cleaner outlet tube. Refer to BODY, AIR CLEANER, REMOVAL AND INSTALLATION .
    GC0193183Courtesy of CHRYSLER GROUP, LLC
  3. Disconnect the right cylinder head lifter deactivation circuit engine oil pressure sensor wire harness connector (1).
  4. Remove the right cylinder head lifter deactivation circuit engine oil pressure sensor (2a) complete with gasket (2b).

INSTALLATION 

GC0194120Courtesy of CHRYSLER GROUP, LLC
  1. Using a NEW  gasket, install the right cylinder head lifter deactivation circuit engine oil pressure sensor (1) and tighten it to the proper specification. Refer to LUBRICATION  .
  2. Connect the right cylinder head lifter deactivation circuit engine oil pressure sensor wire harness connector (2).
  3. Install the right air cleaner outlet tube. Refer to BODY, AIR CLEANER, REMOVAL AND INSTALLATION .
  4. Connect the negative battery cable.