Removal And Installation
REMOVAL
- Disconnect and isolate the negative battery cable.
- Disconnect the mass air flow meter wire harness connection (1).
- Remove the screws (2a), loosen the clamp (2b) and remove the mass air flow meter (2c).
- Remove the O-ring (1) from the air filter housing.
INSTALLATION
- Install a NEW O-ring in the air filter housing.
- Install the mass air flow meter, securely tighten the clamp and screws.
- Connect the mass air flow meter wire harness connection.
- Connect the negative battery cable.