LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Alfa Romeo >> 2019 >> Giulia Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 9 (2.9L Pcm 1 - DTCS P0118-00 To P0350-00) >> Diagnosis And Testing >> P0137-00-O2 Sensor 1/2 Circuit Low >> Possible Causes

Possible Causes

WARNING: This page is about a different variant/trim than selected.
Possible Causes
O2 SENSOR 1/2 SIGNAL CIRCUIT SHORTED TO GROUND
O2 SENSOR 1/2 SIGNAL CIRCUIT SHORTED TO THE O2 SENSOR 1/2 RETURN CIRCUIT
O2 SENSOR 1/2 SIGNAL CIRCUIT SHORTED TO THE O2 SENSOR 1/2 HEATER CONTROL CIRCUIT
O2 SENSOR 1/2
POWERTRAIN CONTROL MODULE 2 (PCM-2)

Always perform the PRE-DIAGNOSTIC TROUBLESHOOTING PROCEDURE before proceeding. Refer to  PRE-DIAGNOSTIC TROUBLESHOOTING PROCEDURE  .