LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Alfa Romeo >> 2019 >> Giulia Base, AWD >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> 2.0L - DTCS P0691-00 To P110F-00 >> DTC Troubleshooting >> P1063-00-Cylinder 3 Oil Supply Solenoid Valve Stuck >> Diagnostic Test

Diagnostic Test

  1. CHECK FOR AN ACTIVE DTC 
    1. Start the engine and allow it to idle.
    2. With the scan tool, read DTCs and record on the repair order.

      Is the DTC active or pending?

      Yes 

      • Go To  2

      No 

  2. CHECK FOR OTHER DTCS 
    1. Refer to the recorded DTCs.

      Is the P1523 DTC active or pending?

      Yes 

      No 

      • Go To  3
  3. CHECK THE ENGINE OIL LEVEL/TYPE/CONDITION 
    NOTE:

    The actuators will not operate if the oil pressure is too low, contaminated or incorrect oil is used.

    1. Check the engine for the following:
      • LOW ENGINE OIL -. Refer to LUBRICATION, DIAGNOSIS AND TESTING .
      • INCORRECT OIL FILTER THAT DOES NOT MEET OEM SPECIFICATIONS
      • OIL DIRTY OR DETERIORATED (Lack of scheduled oil changes)
      • CORRECT OIL VISCOSITY AND WEIGHT
      • ENGINE OIL CONTAMINATED (i.e., coolant and/or fuel)

      Is oil level, type, condition, and filter correct?

      Yes 

      • Go To  4

      No 

      • Correct level/change engine oil and filter as required, consult the Service Information for correct type and grade of engine oil and repeat test.
      • Perform the POWERTRAIN VERIFICATION TEST. Refer to PRE-DIAGNOSTIC TROUBLESHOOTING PROCEDURE .
  4. CHECK THE OIL PRESSURE / ENGINE MECHANICAL 
    1. Remove the Oil Pressure Switch and install a mechanical oil pressure gauge.
    2. Crank the engine for at least 10 seconds and check the oil pressure at the Oil Pressure Switch location.

      Is the oil pressure between 0.8 bar (11.6 psi) and 7.5 bar (108.8 psi) ?

      Yes 

      No