Theory Of Operation

The Evaporative Purge Monitor tests the integrity of the hoses/tube between the throttle body/intake and the fuel tank. The monitor is a two stage test and runs only after the Evap system passes the small leak test. Stage one is non-intrusive. The Powertrain Control Module (PCM) monitors the purge vapor ratio and the Evaporative System Integrity Monitor (ESIM) Switch closed ratio. If the purge vapor ratio is above a calculated value, the monitor passes. If the ESIM switch closed ratio is greater than calculated value when purge flow is greater than a minimum value, the monitor passes. Stage two is an intrusive test and runs only if stage one does not pass. The PCM commands the purge solenoid to flow at a specified rate to force the purge vapor ratio to update. The ratio is compared to a calibrated specification. If it is less than specified, a one trip failure is recorded. This test can detect if the purge hose is off, obstructed, or the purge valve is not operational.