Diagnostic Test
CHECK USING DIAGNOSIS EQUIPMENT
- Connect the diagnosis equipment to the Occupant Restraint Controller and delete the errors in the memory.
Can the Errors in the Occupant Restraint Controller be deleted?
Yes
- End of diagnosis.
No
WARNING:If the Occupant Restraint Controller (ORC) is dropped at any time, it must be replaced. Failure to follow these instructions may result in possible serious or fatal injury.
- Replace the Occupant Restraint Controller (ORC) in accordance with Service Information. Refer to MODULE, OCCUPANT RESTRAINT CONTROL (ORC), REMOVAL AND INSTALLATION .
- Perform the RESTRAINTS SYSTEM VERIFICATION TEST. Refer to STANDARD PROCEDURE .