LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Alfa Romeo >> 2019 >> Giulia Base, AWD >> Repair and Diagnosis >> Restraints >> Restraints Control Systems >> Occupant Restraint Controller (Orc) - DTCS B0003-01 To B0103-1E >> DTC Troubleshooting >> B00D5-14-Passenger Airbag Disable Indicator - Circuit Short To Ground Or Open >> Diagnostic Test

Diagnostic Test

  1. PASSENGER SIDE AIRBAG DEACTIVATION INDICATOR AND CHECK THE OCCUPANT RESTRAINT CONTROLLER CONNECTION 
    1. Check for loose, damaged or corroded connections on the passenger side airbag deactivation indicator and the Occupant Restraint Controller.

      Are there any loose or damaged connections?

      Yes 

      • Repair the wiring connections as necessary.

      No 

      • Go to Step Refer to  2.
  2. PASSENGER SIDE AIRBAG DEACTIVATION INDICATOR AND THE OCCUPANT RESTRAINT CONTROLLER WIRING CHECK 
    1. Check the wiring for an open circuit or high resistance from the passenger side airbag deactivation indicator and pin 22 of connector B on the Occupant Restraint Controller.

      Is there a high resistance or open condition in the wiring?

      Yes 

      • Repair the open circuit or high resistance in the wiring.

      No 

      • Go to Step Refer to  3.
  3. PASSENGER SIDE AIRBAG DEACTIVATION INDICATOR AND THE OCCUPANT RESTRAINT CONTROLLER WIRING CHECK 
    1. Check the wiring from the passenger side airbag deactivation indicator and pin 22 of connector B on the Occupant Restraint Controller for a short to ground.

      Is there a short circuit to ground in the wiring?

      Yes 

      • Repair the wiring and connections as necessary insulation to ground.

      No 