Home >> Alfa Romeo >> 2019 >> Giulia Base, AWD >> Repair and Diagnosis >> Restraints >> Air Bag, SRS >> Occupant Restraint Controller (Orc) - DTCS B0124-01 To U1932-86 >> DTC Troubleshooting >> B012D-96-Driver Door Pressure Sensor (Satellite)-Component Internal Failure >> Diagnostic Test

Diagnostic Test

NOTE:

If the scan tool shows this DTC has a Stored history of setting then the impact/pressure sensor is to be replaced.

VERIFY ACTIVE DTC 

NOTE:

Make sure the battery is fully charged.

  1. Turn the ignition on.
  2. With the scan tool, read ORC DTCs.

    Does the scan tool display an active INTERNAL ELECTRONIC FAILURE DTC or shows a setting history in stored?

    Yes 

    WARNING:

    Turn the ignition off, disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.

    No (Did not set a active or stored INTERNAL ELECTRONIC FAILURE)