Diagnostic Test
- CHECK FOR AN ACTIVE DTC
- With the scan tool, read ORC DTCs and record on the repair order.
- Record the Environmental Data.
- With the scan tool, erase DTCs.
- Using the recorded Environmental Data, along with the When Monitored and Set Conditions above, operate the vehicle in the conditions that set the DTC.
- With the scan tool, read ORC DTCs.
Did the DTC return?
Yes
- Go To 2
No
- Perform the RESTRAINTS SYSTEM INTERMITTENT TEST. Refer to STANDARD PROCEDURE .
- CHECK PYROTECHNIC BATTERY ISOLATION FUSE AND OCCUPANT RESTRAINT CONTROLLER CONNECTIONS
- Check for loose, damaged or corroded connections on the pyrotechnic battery isolation fuse and circuits from the Occupant Restraint Controller.
Are there any loose or damaged connections?
Yes
- Repair the wiring connections as necessary.
No
- Go to Step 3.
- Check for loose, damaged or corroded connections on the pyrotechnic battery isolation fuse and circuits from the Occupant Restraint Controller.
- PYROTECHNIC BATTERY ISOLATION FUSE AND OCCUPANT RESTRAINT CONTROLLER WIRING CHECK
- Check the wiring from the pyrotechnic battery isolation fuse and circuits from the Occupant Restraint Controller for a short to ground.
Is there a short circuit to ground in the wiring?
Yes
- Repair the wiring and connections as necessary insulation to ground.
No
- Go to Step 4.
- Check the wiring from the pyrotechnic battery isolation fuse and circuits from the Occupant Restraint Controller for a short to ground.
- CHECK THE PYROTECHNIC BATTERY ISOLATION FUSE OPERATION
- Check the operation of the pyrotechnic battery isolation fuse.
Is the pyrotechnic battery isolation fuse open?
Yes
- Replace the pyrotechnic battery isolation fuse.
No
WARNING:If the Occupant Restraint Controller (ORC) is dropped at any time, it must be replaced. Failure to follow these instructions may result in possible serious or fatal injury.
- Replace the ORC in accordance with the Service Information. Refer to MODULE, OCCUPANT RESTRAINT CONTROL (ORC), REMOVAL AND INSTALLATION .
- Perform the RESTRAINTS SYSTEM VERIFICATION TEST. Refer to STANDARD PROCEDURE .
- Check the operation of the pyrotechnic battery isolation fuse.