Removal And Installation: Installation
NOTE:
Replacement of the O-ring seal is required anytime an A/C pressure transducer is removed. Failure to replace the rubber O-ring seal may result in a refrigerant system leak.
- Lubricate a new rubber O-ring seal with clean refrigerant oil and install it onto the fitting.NOTE:
Use only the specified O-ring seal as it is made of special material for the refrigerant used in the system. Use only refrigerant oil of the type required for the A/C compressor.
- Install the pressure transducer (1) and tighten to the proper specification. Refer to TECHNICAL SPECIFICATIONS .
- Connect the pressure transducer wire harness connector (2).
- Install the left air cleaner outlet tube. Refer to 2.0L, BODY, AIR CLEANER, REMOVAL AND INSTALLATION or 2.8L, BODY, AIR CLEANER, REMOVAL AND INSTALLATION .
- Connect the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), connect the IBS connector.
- Evacuate the refrigerant system. Refer to PLUMBING, STANDARD PROCEDURE .
- Charge the refrigerant system. Refer to PLUMBING, STANDARD PROCEDURE .