Removal And Installation: Installation
- Position the blower motor into the HVAC housing, and securely tighten the three screws (1b).
- Connect the blower motor wiring harness connector (2).
- Position the Body Control Module (BCM) access cover (1a), install and securely tighten the two cover screws (1a).
- Install the right front floor outlet duct. Refer to OUTLET, AIR, REMOVAL AND INSTALLATION .
- Connect the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), connect the IBS connector.