Set Condition
- The Powertrain Control Module (PCM) detects that the APP Sensor 2 value is below the normal operating range (0.64 volts) but not below the voltage threshold to set the circuit low (short to ground) fault. This diagnostic is designed to detect a sensor that has drifted out of range but is not necessarily open or shorted.