LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Alfa Romeo >> 2019 >> Giulia Base, AWD >> Repair and Diagnosis >> Accessories & Equipment >> Collision/Avoidance >> (Forward Facing Camera Module (FFCM) - Electrical Diagnostics) >> DTC Troubleshooting >> C14AA-68-Calibration Out Of Range - Event Information >> Diagnostic Test

Diagnostic Test

CALIBRATE THE FFCM 

  1. With the scan tool, read Forward Facing Camera Module (FFCM) DTCs and record on the repair order.
  2. With the scan tool, perform the Forward Facing Camera Module calibration procedure.
  3. With the scan tool, erase FFCM DTCs.
  4. Turn the ignition off for ten seconds, then start the engine.
  5. Using the recorded information along with the When Monitored and Set Conditions, operate the vehicle within the conditions that set the DTC.
  6. With the scan tool, read FFCM DTCs.

    Did the DTC return?

    Yes 

    • Replace the FFCM in accordance with the Service Information.
    • Perform the FORWARD FACING CAMERA VERIFICATION TEST. Refer to STANDARD PROCEDURE .

    No 

    • Perform the FORWARD FACING CAMERA VERIFICATION TEST. Refer to STANDARD PROCEDURE .
    • Test complete.