LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Alfa Romeo >> 2019 >> Giulia Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 12 (2.9L Pcm 1 - DTCS P2100-00 To P3405-00) >> DTC Troubleshooting >> P2271-00-O2 Sensor 1/2 Signal Biased Rich >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different variant/trim than selected.
  1. CHECK EXHAUST SYSTEM FOR LEAKS 
    1. Check for leaks in the exhaust system.

      Are there any leaks?

      Yes 

      • Repair the leaks as necessary and restore correct operation.
      • Perform the POWERTRAIN VERIFICATION TEST. Refer to POWERTRAIN VERIFICATION TEST .

      No 

      • Go To  2
  2. CHECK CONNECTION FOR THE O2 SENSOR 1/2 AND THE PCM-1 
    1. Check for loose, damaged or corroded connections on the O2 Sensor 1/2 or the PCM-1.

      Are there any loose or corroded connections?

      Yes 

      • Repair the wiring connections as necessary.
      • Perform the INTERMITTENT CONDITION diagnostic procedure. Refer to INTERMITTENT CONDITION .

      No 

      • Go To  3
  3. CHECK PCM-1 AND O2 SENSOR 1/2 WIRING 
    1. Check the wiring for an open circuit or high resistance between the O2 Sensor 1/2 and (K904) of the connector on vehicle side of the PCM-1.

      Is there a high resistance or open condition in the wiring?

      Yes 

      • Repair the open circuit or high resistance in the wiring.
      • Perform the INTERMITTENT CONDITION diagnostic procedure. Refer to INTERMITTENT CONDITION .

      No 

      • Go To  4
  4. CHECK PCM-1 AND O2 SENSOR 1/2 WIRING 
    1. Check for a short circuit in the wiring between the O2 Sensor 1/2 and (K904) of the connector on vehicle side of the PCM-1.

      Is there a short circuit in the wiring?

      Yes 

      • Repair the short circuit in the wiring.
      • Perform the INTERMITTENT CONDITION diagnostic procedure. Refer to INTERMITTENT CONDITION .

      No 

      • Go To  5
  5. CHECK O2 SENSOR 1/2 OPERATION 
    1. Check that the O2 Sensor 1/2 is working properly.

      Is the O2 Sensor 1/2 operation incorrect?

      Yes 

      • Replace the O2 Sensor 1/2.

      No